Outdoor Units – JR8V VRV Vertical Discharge Series

Contact Us to Inquire About This Product

Outdoor Units – JR8V VRV Vertical Discharge Series

oitVRV System allowing independent zone control

Models from 21,670 to 57,620 BTU

Modular installation capacity with up to 3 outdoor units

Full DC Inverter Technology

Full DC Inverter Compressor EVI System

Automatic mode adjustment with 10 priority modes

Automatic address assignment for all indoor and outdoor units

Quadruple compressor oil control

Quadruple failure protection system

150% connectivity* (prior schematic verification required)

Total piping length up to 1,100 meters

Main Features

VRV system allowing independent zone control

Seasonal Coefficient of Performance (SCOP) up to 4.37

Seasonal Energy Efficiency Ratio (SEER) up to 7.33

Full DC Inverter Technology

Full DC Inverter Compressor EVI System that increases refrigerant circulation, enhancing cooling and heating capacity

Microchannel heat exchanger providing refrigerant cooling up to 15ºC, improving heat transfer efficiency and reducing refrigerant flow noise

For installations with temporary power supply restrictions, the outdoor unit supports 60 energy management levels, adjustable between 40–100% output in 1% increments. Prevents demand from exceeding supply, ensuring continuous operation

Low standby power consumption under 3.5W

Low noise level with silent mode offering 15 options and nighttime silent mode

Intelligent defrosting technology to avoid heat loss

Fully sealed electrical control box for protection against damage

Equipped with 19 sensors to monitor refrigerant conditions throughout the piping, calculating quantity in real time

Smart evaporation system: the unit calculates room size and insulation efficiency according to temperature loss, automatically adjusting evaporation temperature (in Cooling) and condensation temperature (in Heating). Each indoor unit then regulates airflow and refrigerant flow accordingly to ensure comfort and maximum efficiency

In modular systems and units with two compressors, operating time is balanced across units/components to extend lifespan

Quadruple fault protection system:

  1. In modular systems, if one unit fails, the system keeps running

  2. In one unit, if a fan fails, the other continues to maintain performance

  3. In units with two compressors, if one fails, the other continues operating

  4. If sensor failure occurs, remaining sensors can activate a virtual recovery sensor to keep the system running

Automatic snow-blowing function to prevent buildup on the unit

Self-cleaning function to avoid dust accumulation

Maximum height difference between indoor and outdoor units up to 110 meters

Wide operating range – Cooling: -15ºC to 55ºC / Heating: -30ºC to 30ºC

Automatic refrigerant charging and recycling

Two-wire non-polar connection for flexible installation, avoiding communication wiring errors (up to 1200 meters)